Valve Seriers - Check Valve Seriers
FLEX CLOCK CHECK VALVE SFCV /ENH44X
A. FLEX CLOCK CHECK VALVE STRUCTURE CHARACTERISTICS AND USAHE

FLEX CLOCK CHECK VALVE
Suitable for the water supply and drainage system, mounted in the pipeline or on the pump outlet, prevent both pump and pipeline from being damaged due to medium's back-flow and water hammer. It can also be mounted on the by-pass pipe for water in and out of a reservoir to assist the water of the reservoir to flow back to the water supply system.
B. FLEX CLOCK CHECK VALVE MAIN TECHNICAL PARAMETER
| PN(MPa) | 1.0 | 1.6 | 2.5 | |
| Test pressure (MPa) |
Shell strength | 1.5 | 2.4 | 3.75 |
| Sealing performance | 1.1 | 1.76 | 2.75 | |
| Working temperature | ≤80℃ | |||
| Applicable medium | Rinsing、Dead oil | |||
C. FLEX CLOCK CHECK VALVE MATERIAL FOR MAIN PARTS
| Name of parts | Material |
| Body、Valve casing | Casting pig、Ductile iron |
| Disc | Rubber assembly |
| Spring | Stainless steel |
D. FLEX CLOCK CHECK VALVE MAIN EXTERNAL AND CONNECTION DIMENSIONS
| DN mm | PN1.0 | PN1.6 | PN 2.5 | |||||||||||||||||||||
| L | b | f | D2 | D | D1 | Z-φd | H | L | b | f | D2 | D | D1 | Z-φd | H | L | b | f | D2 | D | D1 | Z-φd | H | |
| 40 | 165 | 18 | 2 | 85 | 150 | 110 | 4-18 | 180 | 165 | 18 | 2 | 85 | 150 | 110 | 4-18 | 180 | 165 | 18 | 2 | 85 | 150 | 110 | 4-18 | 180 |
| 50 | 200 | 20 | 3 | 102 | 165 | 125 | 4-18 | 190 | 200 | 20 | 3 | 102 | 165 | 125 | 4-18 | 190 | 200 | 20 | 3 | 99 | 165 | 125 | 4-18 | 190 |
| 65 | 215 | 20 | 3 | 122 | 185 | 145 | 4-18 | 210 | 215 | 20 | 3 | 122 | 185 | 145 | 4-18 | 210 | 215 | 22 | 3 | 118 | 185 | 145 | 8-18 | 210 |
| 80 | 240 | 22 | 3 | 133 | 200 | 160 | 8-18 | 230 | 240 | 22 | 3 | 133 | 200 | 160 | 8-18 | 230 | 240 | 24 | 3 | 132 | 200 | 160 | 8-18 | 230 |
| 100 | 290 | 24 | 3 | 158 | 220 | 180 | 8-18 | 250 | 290 | 24 | 3 | 158 | 220 | 180 | 8-18 | 250 | 290 | 24 | 3 | 156 | 235 | 190 | 8-22 | 250 |
| 125 | 330 | 26 | 3 | 184 | 250 | 210 | 8-18 | 280 | 330 | 26 | 3 | 184 | 250 | 210 | 8-18 | 280 | 330 | 26 | 3 | 184 | 270 | 220 | 8-26 | 280 |
| 150 | 355 | 26 | 3 | 212 | 285 | 240 | 8-22 | 315 | 355 | 26 | 3 | 212 | 285 | 240 | 8-22 | 315 | 355 | 28 | 3 | 211 | 300 | 250 | 8-26 | 315 |
| 200 | 500 | 28 | 3 | 268 | 340 | 295 | 8-22 | 370 | 500 | 30 | 3 | 268 | 340 | 295 | 12-22 | 370 | 500 | 30 | 3 | 274 | 360 | 310 | 12-26 | 370 |
| 250 | 620 | 28 | 3 | 320 | 395 | 350 | 12-22 | 430 | 620 | 32 | 3 | 320 | 405 | 355 | 12-26 | 430 | 620 | 32 | 3 | 330 | 425 | 370 | 12-30 | 430 |
| 300 | 700 | 28 | 4 | 370 | 445 | 400 | 12-22 | 475 | 700 | 32 | 4 | 370 | 460 | 410 | 12-26 | 475 | 700 | 34 | 4 | 389 | 485 | 430 | 16-30 | 475 |
| 350 | 785 | 30 | 4 | 428 | 500 | 460 | 16-22 | 550 | 785 | 36 | 4 | 428 | 520 | 470 | 16-26 | 550 | 785 | 38 | 4 | 450 | 555 | 490 | 16-33 | 550 |
| 400 | 915 | 32 | 4 | 482 | 565 | 515 | 16-26 | 600 | 915 | 38 | 4 | 482 | 580 | 525 | 16-30 | 600 | 915 | 40 | 4 | 505 | 620 | 550 | 16-36 | 600 |
E. FLEX CLOCK CHECK VALVE SCHEMATIC DIAGRAM OF INSTALLATION

FLEX CLOCK CHECK VALVE
The technical data subject to amend without notice