
Valve Seriers - Check Valve Seriers
SMALL RESISTANCE SLOW-CLOSE CHECK VALVE ENHH44X/T/H
A. SMALL RESISTANCE SLOW-CLOSE CHECK VALVE STRUCTURE CHARACTERISTICS AND USAHE
small resistance slow-close check valve is a safety device mounted in the pipeline or pump outlet to prevent the pump from inversed running due to the water hammer's shock produced in the side-flow of the medium when the pump stops. And it features by the light flap, big opening, notable power saving, small fluid resistance, new-style of water hammer removal mechanism's design, stable and reliable seal performance, wearable, long duration, stable running, without vibration and noise etc.
Suitable for the pipeline related to the systems of water supply and drainage, fire-fighting, warming etc. or the pump outlet to prevent both pump and pipeline from being damaged due to the water hammer produced in medium's back-flow.
B. SMALL RESISTANCE SLOW-CLOSE CHECK VALVE STRUCTURE DRAWING



SMALL RESISTANCE SLOW-CLOSE CHECK VALVE
C. SMALL RESISTANCE SLOW-CLOSE CHECK VALVE MAIN TECHNICAL PARAMETER
| PN(MPa) | 1.0 | 1.6 | 2.5 | |
| Test pressure (MPa) |
Shell strength | 1.5 | 2.4 | 3.75 |
| Sealing performance | 1.1 | 1.76 | 2.75 | |
| Working temperature | ≤80℃ | |||
| Applicable medium | Rinsing, Dead oil | |||
D. SMALL RESISTANCE SLOW-CLOSE CHECK VALVE MATERIAL FOR MAIN PARTS
| Name of parts | Body, Bonnet | Seat | Valve shaft |
| Material | Casting pig, Ductile lron, Bowl-shape steel | Rubber assembly | Stainless steel |
E. SMALL RESISTANCE SLOW-CLOSE CHECK VALVE MAIN EXTERNAL AND CONNECTION DIMENSIONS
| DN mm | ENHH44X/T/H-1O | |||||||
| L | D | D1 | B | H | H1 | B | Z-φd | |
| 40 | 200 | 150 | 110 | 220 | 300 | 140 | 20 | 4-18 |
| 50 | 230 | 165 | 125 | 270 | 300 | 140 | 20 | 4-18 |
| 65 | 290 | 185 | 145 | 290 | 320 | 150 | 20 | 4-18 |
| 80 | 310 | 200 | 160 | 315 | 330 | 162 | 22 | 8-18 |
| 100 | 350 | 220 | 180 | 340 | 460 | 260 | 24 | 8-18 |
| 150 | 480 | 285 | 240 | 402 | 580 | 274 | 26 | 8-22 |
| 200 | 500 | 340 | 195 | 470 | 680 | 302 | 28 | 8-22 |
| 250 | 600 | 391 | 350 | 550 | 730 | 348 | 28 | 12-22 |
| 300 | 700 | 445 | 400 | 622 | 850 | 370 | 28 | 12-22 |
| 350 | 800 | 505 | 460 | 660 | 950 | 410 | 30 | 16-22 |
| 400 | 900 | 565 | 515 | 800 | 1030 | 450 | 32 | 16-26 |
| 500 | 1100 | 670 | 620 | 950 | 1262 | 550 | 34 | 20-26 |
| 600 | 1300 | 780 | 725 | 1122 | 1520 | 635 | 36 | 20-30 |
| 700 | 1400 | 895 | 840 | 1810 | 1644 | 720 | 40 | 24-30 |
| 800 | 1500 | 1015 | 950 | 1250 | 1774 | 780 | 44 | 24-33 |
| 900 | 1700 | 1115 | 1050 | 1470 | 2084 | 920 | 46 | 28-33 |
| 1000 | 1900 | 1230 | 1160 | 1570 | 2195 | 970 | 50 | 28-36 |
| 1200 | 2220 | 1450 | 1380 | 1920 | 2615 | 1150 | 56 | 32-39 |
F. SMALL RESISTANCE SLOW-CLOSE CHECK VALVE SCHEMATIC DIAGRAM OF INSTALLATION

SMALL RESISTANCE SLOW-CLOSE CHECK VALV
The technical data subject to amend without notice